11.4.3   Thermal shock

 

The drain lines at the upstream section of the control valves serve a dual function. As well as maintaining the pipework free from water, they also maintain the valve bodies at a temperature which will avoid any large thermal shock to the valves when the by-pass comes into operation.

 